Calculating Pipe Length

How to calculate practical length of pipe is mentioned as below in consideration of length of pipe to be inserted into joint. Take into consideration of length between the both of joint centers, calculate practical pipe's length.

 

Plastic Joint

Plastic Joint 

 

ø28 Metal Joint

ø28 Metal Joint 

 

ø32 Metal Joint

ø32 Metal Joint 

 

Strength Of Pipe

Limits of temperature for actual use

The temperature for practical use of ABS resin for Pipe & Joint is limited to -10℃ ~ 80℃. So please avoid the place of which temperature is out of the limit or place near heat or fire.

Regarding Strength of Logiform Pipe and Plastic Joint

Like other materials such as steel, aluminum and wood, the strength of Logiform structures rely on the design and assembly techniques. In case of establishing structures with LOGIFORM pipes, proper strength to fit its utility objective and safety must be considered to design. The structure required special strengh is necessary to be manufactured with strengthful stability, which can be asked to our office anytime.

   Regarding Strength of Logiform Pipe and Plastic Joint    Regarding Strength of Logiform Pipe and Plastic Joint   Regarding Strength of Logiform Pipe and Plastic Joint  
Proportional Margin
Load Approx.
110 kg   170 kg   230 kg  
 
Concentrated load on half point of the pipe/Speed of testing : 2kg/min
Normal temperature
 

 

The Strength of LOGIFROM PIPE

Proportional Margin Loads of 450, 1000, 1800mm of pipes are as follow.

The Strength of LOGIFROM PIPE
A(Dimension) ¨ª28 ¨ª32
450mm Approx.170kg Approx.180kg
1000mm Approx.80kg Approx.90kg
1800mm Approx.40kg Approx.44kg
[Testing Condition]
Simply supported both sides of pipe
Concentrated load on the center of the pipe
Force rate:2kg/min
Temperature : Normal

 

Compression Strength

Max. compression load as 1,752kgs in case of below model (Applied with metal joint HJ-2)

Strength Of Pipe [Test Condition]
Compression Speed :100mm/min
Normal Temperature
Load applied impartially on four edges as up and down paralyzed.

 

Strength

Max. Tension Strength is 800kgs after a week since Logiform Pipe was attached with plastic joint(J-2B)

[Test Condition]
Tension Speed : 200mm/min                  Normal Temperature

Regarding Stability

Sufficient stability is needed to be considered as constructing of a structure. Those of fixed load as 1/3, repetition load as 1/5, impact load as 1/12 are preferable in consideration of above mentioned of strength, load. Please avoid the case of improper utility by using Logiform pipe, appropriate application with this is recommended.

[1] Max. Holding strength of Logiform Pipe attached with metal joints against horizontal, vertical pulling force is 80kgs

[Test Condition]
A force was applied on center of the pipe, force rate 1kg/min under Normal Temperature

Strength Of Pipe 

[02] These tests were performed at room temperature, force rate was 1kg/min, a force was applied on the center of the pipe

Strength Of Pipe 

[03] The maximum force withstood by the shelf made of 28Ø pipes and joints in this example was 200kg(440lbs) before slipping occurred.



[Testing Condition]
A downward force was applied evenly on a shelf at room temperature
and force rate was 3kg/min

Strength of Ø32 metal joint

[01] In case pulling force was applied vertically, horizontally on Logiform Pipes attached with metal joints.

Pulling Rate : 5 mm/min               Normal Temperature.

Strength of Ø32 metal joint 

[02] Proportional Margin Load of Logiform Pipe attached with metal joints as follow when 1,000mm of distance between center of both joints is applied.

Force applied in the center of the pipe, force rate:1kg/min, normal temperature

Strength of Ø32 metal joint 

 

Application Notice

The above examples refer to metal joints which have been attached at the recommended torque of 9.8N * m (100kg *m or 7 1/4 *ft). Please tight firmly not to be loosen. These results will not be duplicated with other torque values, or in cases where pipe other than Logiform standard pipe is used. Also they are actual test values without any safety factors added.

- Yield strength refers to the point where any further force would permanently deform the pipe.

 

Manufacturing Sequence & Check Points 

In order to manufacture pipes, joint's materials, piling-up vehicles, piling-up stand and sliding rack, etc as per customer's purpose and concept. it's necessary to keep sequence and check points as the following;

1st View usage purposes, analysis of load conditions, usage surroundings, etc for products to be manufactured 

2nd Design

3rd To start and check 

4th Mass production